Hioki 3153 Automatic Insulation/Withstanding HiTester

Sale price0,00 kr Price on quotation
Available

Use our chat for personal support. Or contact us via +45 31 33 18 19 or salg@GOmeasure.dk


The Hioki electrical safety testers are designed for insulation resistance and voltage withstand testing of electrical devices and components according to various safety standards. The 3153 is an automatic insulation and AC/DC voltage withstanding tester that fully supports automated testing.

Discover the possibilities

More information

Hioki 3153 Automatic Insulation/Withstanding HiTester


The Hioki electrical safety testers are designed for insulation resistance and voltage withstand testing of electrical devices and components according to various safety standards. The 3153 is an automatic insulation and AC/DC voltage withstanding tester that fully supports automated testing.

Key Features

• Programmable insulation (50 to 1,200 V DC) and dielectric strength (AC/DC) testing

• Program up to 32 files of test types, test points (50 steps), and measurement settings

• Optional scanner for multipoint automatic testing

• Uses the PWM method to generate accurate test voltages that do not depend on the supply voltage

• Ramp timer function for increasing or decreasing the applied voltage during dielectric strength testing at user-specified times
 

■ Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

FunctionsProgram up to 32 files of 50 step test settings.10 sets each of dielectric strength and insulation test settings, hold, buzzer
Monitor functionsOutput voltage, detected current, measured resistance, Refresh rate: 2 times/s
Power supply100 to 120 V, 200 to 240 V AC, (50/60 Hz), 1000 VA max.
Dimensions and mass320 mm (12.60 in) W × 155 mm (6.10 in) H × 480 mm (18.9 in) D, 18 kg (634.9 oz)
AccessoriesH.V. Test Lead 9615 (high voltage side and return, 1 each) ×1, Power cord ×1, Instruction manual ×1, Spare fuse ×1

[Withstanding test]

Testing voltage AC/DC0.2 kV to 5.00 kV AC, 500 VA (max. 30 minutes), 0.2 kV to 5.00 kV DC, 50 VA (continuance)
Voltage settingDigital setting (0.01 kV setting resolution)
Waveform/FrequencySine wave (5% or less distortion, unloaded), 50/60 Hz selectable
Current measurement0.01 mA to 100.0 mA, Average rectified display (Digital)
Measurement range10 mA (0.01 mA resolution), 100 mA (0.1 mA resolution)
VoltmeterDigital: accuracy ±1.5 % f.s. (f.s.=5.00 kV) (Average rectified display)
Decision methodWindow comparison (digital settings)

[Insulation test]

Rated testing voltage50 to 1,200 V DC (in 1 V steps)
Rated testing current1 mA, Short-circuit current: 200 mA or less
Measurement range/accuracy0.10 to 9999 MΩ, 4 ranges, ± 4 % rdg. (representative values for 0.5 MΩ to 1,000 MΩ)
Decision methodWindow comparison (digital settings)

[Timer]*Test times may differ from set timer times depending on the load.

Setting range0.3 to 999 s
Ramp/delayTesting voltage ramp-up, or down, Insulation test delay: 0.1 to 99.9 s