Hioki 3273-50 Clamp On Probe

Sale price18.960,00 kr
23.700,00 incl. VAT
Available

Use our chat for personal support. Or contact us via +45 31 33 18 19 or salg@GOmeasure.dk


  • Clamp on probe
  • DC to 50MHz (−3dB)
  • 30 Arms maximum
  • 5 mm core diameter

Discover the possibilities

More information

Hioki 3273-50 Clamp On Probe

Hioki flat bandwidth current probes are best-in-class current sensors for use with Memory HiCorders and high performance oscilloscopes. The Hioki 3273-50 offers a wide DC to 50 MHz bandwidth and 30A of continuous input, and applications include capturing transient current signals from switching power supplies, inverters, and motor controllers. 
The probe is designed with a high permeability magnetic shield to reduce the effects of electric fields, making it ideal for measuring low currents or nearby high-current lines. 

Use with an instrument with a high input impedance of 1 MΩ or higher. 
 

Paired with the zero-flux method, a proprietary thin-film Hall element makes possible high-performance current sensors.

Wideband current sensors use the "zero flux method (Hall element detection type)" to measure. High-frequency currents are detected with the winding (CT method), and low frequency currents including DC are detected with the "Hall element." 

● Hall element detection 
Hall element detection is characterized by a simple structure and a sensor section that can easily be downsized. Hioki combines our own proprietary thin-film Hall elements with the zero flux method to deliver sensors that can conduct measurements over a wide range of frequencies, from DC to MHz bands. 
Ideal for waveform observations using a MEMORY HiCORDER or oscilloscope, Hall element detection achieves a high S/N ratio in the wideband range, making them particularly well-suited for design verification of electronic circuitry such as high-speed signal circuits. 

● Zero flux method 
The zero flux method is a measurement method used in both high-accuracy and wideband sensors. As the principles the sensor is based on give it both low operating magnetic flux level and low insertion impedance, it is characterized by its lack of influence on the measured object and low instrument loss. 
Hioki 3272 
 

Key Features

  • Waveform observation across a wide band from DC to 50 MHz
  • Connects directly to oscilloscope or Memory HiCorder BNC input terminal (*1)
  • High S/N characteristics enable the measurement of 10 mA order current waveforms (3273-50, 3276)


*1:Connecting the probe's metal BNC terminal to a Memory HiCorder’s plastic BNC terminal may distort or damage the plastic terminal. To avoid damage, please connect and disconnect the probe cable straight to the BNC terminal of the waveform monitoring equipment. 
 

Basic specifications

Accuracy guaranteed: 1 year

Frequency bandwidthDC to 50 MHz (-3 dB)
Rise time7 ns or shorter
Noise level2.5 mA rms max. (bandwidth limited to 20 MHz)
Continuous allowable input30 A rms (requires derating at frequency)
Max. allowable peak input50 A peak (non continuous)
Amplitude accuracy (30 min. after power-on, after degaussing and zero-adjustment)±1.0 % rdg. ±1 mV f.s. (DC, 45 to 66 Hz, 0 to 30 A rms) ±2 % rdg. (DC, 45 to 66 Hz, 30 A rms to 50 A peak)
Output rate0.1 V/A (The output of this probe is internally terminated)
Measurable conductorsInsulated conductor
Core diameterφ 5 mm (0.20 in)
Power supply±12 V ±0.5 V, 5.6 VA max.
Dimensions and mass±1.0 % rdg. ±1 mV f.s. (DC, 45 to 66 Hz, 0 to 30 A rms) ±2 % rdg. (DC, 45 to 66 Hz, 30 A rms to 50 A peak) Sensor cable BNC terminal: 1.5 m (4.92 ft), Power cable: 1 m (3.28 ft)
Included accessoriesInstruction manual ×1, Soft case × 1

 

For more information: Hioki