Hioki 3283 Clamp on Leak HiTester
Price on request
1mA to 200A AC Leakage Current Clamp Meter with 10 µA Resolution to Analyze Distorted Waveforms
Out of stock
Hioki 3283 Clamp on Leak HiTester
Hioki clamp meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. The Hioki 3283 series are leakage current handheld clamp meters with a 10mA to 200A range and 10 μA resolution. Model 3283 has output capabilities for advanced monitoring on recording equipment, and Model 3283-20 complies with EN 61010-2-032:2012 Type A standards to measure uninsulated hazardous live conductors such as busbars.
CAT III 300 V: 3283-20
Key Features
• Measure leak current using highly sensitive 10μA resolution (at 10.00 mA range)
• Indicate 50/60 Hz leak current components with the filtering function
• Monitor leak current conditions in combination with a Memory HiCorder (monitor output, Model 3283 only)
• 3283-20: EN 61010-2-032:2012 Type A to measure uninsulated hazardous live conductors such as busbars
Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
3283 | 3283-20 | |
AC Current range | 10.00 m/ 100.0 m/ 1.000/ 10.00/ 200.0 A, 5 ranges, (40 Hz to 2 kHz, True RMS), Basic accuracy: ±1.0 % rdg. ±5 dgt., Guaranteed accuracy: from 1.00 mA | |
AC Voltage range | N/A | |
Frequency range | 30.0 Hz to 1000 Hz, 2 ranges, Basic accuracy: ±0.3 % rdg. ±1 dgt. | |
Crest factor | 2.5 or less (1.5 at 200 A range) | |
Filter function | Cut off frequency at filter ON: 180 Hz (-3dB) | |
Output | REC output for current: DC 1 V/f.s. (2 V/f.s. at only 200 A range), response time: less than 200 ms. MON output for current: AC 1 V/f.s. (2 V/f.s. at only 200 A range), 5 Hz to 15 kHz frequency bandwidth (-3 dB) |
N/A |
Other functions | Max./ Min./ Average value record, Data hold, Auto power off | |
Display | LCD, max. 2000 dgt., Display refresh rate: 4 times/s (Fast), 1 time/3s (Slow), 4 times/s (bar graph) | |
Power supply | 6LR61 (Stacked alkaline battery) ×1, or 6F22 (Stacked manganese battery), Continuous use: 40 hours (using 6F22), AC adapter 9445-02/-03 |
6LR61 (Stacked alkaline battery) ×1, or 6F22 (Stacked manganese battery), Continuous use: 40 hours (using 6F22) |
Core jaw dia. | φ 40 mm (1.57 in) | |
Dimensions and mass | 62 mm (2.44 in) W × 225 mm (8.86 in) H × 39 mm (1.54 in) D, 400 g (14.1 oz) |
|
Accessories | Carrying case 9399 ×1, Hand strap ×1, Stacked manganese battery (6F22) ×1, Instruction manual ×1 | Carrying case 9399 ×1, Hand strap ×1, Alkaline battery (6LR61) ×1, Instruction manual ×1 |
Link to Hioki: 3283 on Clamp Leak HiTester
Hioki 3283 Clamp on Leak HiTester
Hioki 3283 Clamp on Leak HiTester
Carrying Case 9399
Additional information
Producent | Hioki |
---|---|
Produktkategori | Electrical Safety Testers |