+45 31 33 18 19
salg@GOmeasure.dk

Hioki 8423 Memory HiLogger

Hioki 8423 Memory HiLogger

14.010,00 kr.

  • Memory HiLogger
  • 15ch to 600ch isolated input
  • DC Voltage/ temperature
  • Thermocouple or Platinum sensor/ Humidity/ Cumulative pulses/ Rotations/ Digital measurement
  • minimum 10 ms interval
  • LAN/ USB Communication
  • PC base data acquisition
  • Main unit only

Hioki 8423 Memory HiLogger

Hioki Memory HiLoggers are high-speed data loggers for recording multiple chanels of voltage, temperature, resistance, humidity, rotation, and pulse signals, providing complete isolation within channel sets. The 8423 with optional input modules log data at 10ms speeds across up to 600 simultaneously, and is configurable and controllable using a PC.

Key Features

  • Capture data with 15 to a maximum of 600 channels
  • Send data to the PC in real time
  • Isolated to sustain up to 600 V between modules and earth
  • USB 2.0, LAN 100BASE-TX, store to 1GB PC Card
  • Simultaneous fast- and low-speed sampling allows for media storage space efficiency

Basic specifications

Accuracy guaranteed: 1 year
No. of connectable units Maximum 8 units (total 120 channels), Bundle 8 modules together to achieve a 120-channel system, Bundle 5 systems together to enable a maximum of 600 channels of simultaneous recording
Measurement parameters
Model 8948
[No. of channels] 15 analog channels, isolated scanning method input (2 terminals: M3 screw type)
[Voltage measurement range] ±150 mV to ±100 V, 1-5V, Max. resolution 5 µV, Max. allowable input: 100 VDC, between channels: 200 VDC, to earth: 600 VAC/DC
[Temperature range] -200˚C to 2000˚C (depend on the sensor), thermocouples (K, J, E, T, N, R, S, B, W), Max. resolution 0.01˚C
Measurement parameters
Model 8949
[No. of channels] 15 analog channels, isolated scanning method input (4 terminals: push-button type) (not isolated between channels at resistance temperature sensor & humidity sensor)
[Voltage measurement range] ±150 mV to ±60 V, 1-5V, Max. resolution 5 µV, Max. allowable input: 60 VDC, between channels: 120 VDC, to earth: 600 VAC/DC
[Temperature range] −200˚C to 2000˚C (depend on the sensor), thermocouples (K, J, E, T, N, R, S, B, W), Max. resolution 0.01˚C
[Resistance temperature sensor range] −200˚C to 800˚C, (Pt 100, JPt 100), Max. resolution 0.01˚C
[Humidity] 5.0 to 95.0% rh, (use with optional sensor 9701), resolution 0.1% rh
Measurement parameters
Model 8996
[No. of channels] 15 channels, digital/pulse input (2 terminals: M3 screw type, CH1-5, CH6-10, CH11-15 are common GND, No-voltage ‘a’ contact, open collector or voltage input)
[Totalized pulses] 0 to 1000M pulse, Max. resolution 1 pulse
[Rotation count] 0 to 5000/n (r/s), Resolution 1/n (r/s) *n = pulses per rotation (1 to 1,000)
[Digital input] Record ON/OFF digital signal per interval
[Max. allowable input] 50 VDC, between channels: 33 VACrms or 70 VDC, to earth: 600 VAC/DC, (Upper limit voltage that does not cause damage when applied between CH1-5, CH6-10, CH11-15 each channel and chassis, and between each UNITs)
Recording intervals 10 ms to 1 hr, 19 ranges (5s to 1hr when combined with humidity measurement), Dual sampling: Recording intervals can be specified for every input module (high-speed and low-speed)
Function Measurement data are saved to the CF Card in real time, Trigger function, Digital filter (Input unit), Alarm output (use with the Alarm unit 8997), Data acquisition is controlled by the PC data acquisition program, FTP server function, HTTP server function
Interface LAN: supports 100Base-TX, USB: Ver 2.0, mini-B receptacle, CF card slot
Power supply Using the AC adapter 9418-15 (100 to 240 V, 50/60 Hz), 55 VA Max. (include AC adapter), 20 VA Max. (main unit only) (when connected with 8 units),
External DC Power: 9.6 V to 15.6 VDC, 20 VA Max. (when connected with 8 units) (Please contact HIOKI for connection cord)
Dimensions and mass 67 mm (2.64 in) W × 133 mm (5.24 in) H × 125 mm (4.92 in) D, 600 g (21.2 oz) (main unit 8423 only)
Included accessories Quick start manual × 1, Instruction manual × 1, AC adapter 9418-15 × 1, USB cable × 1, CD-R (data collection software “Logger Utility”) × 1, Connector cover × 1, Ferrite clamp × 1, Connection plate × 1

Combination status with LabVIEW or MATLAB script

Compatible models LabVIEW MATLAB script
8423 OK N/A

Introducing a multichannel logger that can be expanded to accommodate various applications

The 8423 can be expanded with up to eight input modules. Four different types of module can be mixed and matched to accommodate specific applications.

Adding an input module is easy thanks to one-touch installation. And since the 8423 can be mounted on industry-standard DIN rails, it’s ideal for use in embedded and rack-mounted applications.

Hioki 8423

Introducing a multichannel logger that can measure up to 40 modules (600 channels)

A single 8423 can be expanded with up to eight input modules (for a total of 120 channels).
Those eight modules constitute one system, and the product can be expanded to include up to five systems (providing the ability to measure 600 channels).

What’s more, data can be collected from all 600 channels in as little as 10 msec, making the 8423 ideal for use in measurement applications that involve rapid fluctuations in load, for example hybrid vehicles.

Hioki 8423

All-Channel Synchronous Measurement Capability

When measuring up to 120 channels on combined modules, all input channels are sampled synchronously. When multiple 8423s are connected via LAN or USB for measuring up to 600 channels, the sampling of each instrument in the system can be synchronized using optional Connection Cable Model 9683.

As well as PC-based data collection, measurement start and stop can be controlled by the [START/MARK] and [STOP] keys on a master 8423.

Note: Any 8423 may be designated as the master.
Only the initial acquisition criteria setting needs to be performed on a PC via USB or LAN.

Hioki 8423

Isolated to sustain up to 600 V between modules and earth

With all channels isolated and a 600V AC/DC maximum rated voltage to earth, even when the common mode voltage increases as is common with layered batteries, the voltage of each individual battery cell can be safely measured.

Hioki 8423

Included PC application with measurement and analysis functionality

The supplied Logger Utility software enables processing of measurement data on a PC.

Use the supplied Logger Utility software to record data on a PC in real-time. View past data during recording.

Connect the PC to the HiLOGGER using USB or via LAN.

Hioki 8423

For more information: Hioki

Hioki 8423 Memory HiLogger

Hioki 8423 Datasheet

Additional information

Producent

Hioki

Produktkategori

Switching and Data Aquisition

This website uses cookies. By continuing to use this site, you accept our use of cookies.  Learn more