+45 31 33 18 19
salg@GOmeasure.dk

Hioki IM3536 LCR Meter

Hioki IM3536 LCR Meter

38.690,00 kr.

General-Purpose LCR Meters with Measurement Frequency from DC, 4 Hz to 8 MHz

SKU: IM3536 Category: Tag:

Hioki IM3536 LCR Meter

Hioki LCR Meters and Impedance Analyzers range from 1mHz to 3GHz devices to suit a wide range of applications in the testing of electronic components. The IM3536 raises the industry standard for general-purpose LCR meters by offering a wide DC and 4Hz to 8MHz (up to 10MHz special order available) testing frequency while delivering 0.05% accuracy, ideal for evaluating the characteristics of next generation electronic components, including power supply inductors thanks to the instrument’s maximum measurement frequency of 8MHz. (up to 10MHz special order available)

Key Features

  • DC, 4 Hz to 8 MHz measurement frequency
  • High-speed measurement of 1 ms (fastest time)
  • High-precision measurement of ±0.05% rdg. (representative value)
  • Guaranteed accuracy range from 1 mΩ, low-impedance measurement with unmatched repeatability
  • DC bias function: Measure under conditions simulating actual use or in accordance with industry standards
  • Exceptional specifications and cost-performance for a wide range of applications, from R&D to production lines

Hioki IM3536 LCR Meter

Hioki IM3536 LCR Meter Datasheet

Hioki IM3536 LCR Meter

SMD TEST FIXTURE IM9100

• High-precision four-terminal measurement • For direct connection meters • Test SMDs with electrodes on the bottom

Learn more

 

4-TERMINAL PROBE 9140-10

Cable length 1 m (3.28 ft), DC to 200 kHz, impedance characteristics of 50 Ω, 4-terminal pair configuration, measurable conductor diameter: ø0.3 (0.01 in) to 5 mm (0.20 in)

 

TEST FIXTURE 9261-10

Cable length 1 m (3.28 ft), DC to 8 MHz, impedance characteristics of 50 Ω, 4-terminal pair configuration, measurable conductor diameter: ø0.3 (0.01 in) to 1.5 mm (0.06 in)

 

TEST FIXTURE 9262

Direct connection type, DC to 8 MHz, measurable conductor diameter: ø0.3 (0.01 in) to 2 mm (0.08 in)

 

SMD TEST FIXTURE 9263

Direct connection type, DC to 8 MHz, Test sample dimensions:1 mm (0.04 in) to 10 mm (0.39 in)

 

DC BIAS VOLTAGE UNIT 9268-10

Direct connection type, 40 Hz to 8 MHz, maximum applied voltage of DC ±40 V

 

DC BIAS CURRENT UNIT 9269-10

Direct connection type, 40 Hz to 2 MHz, maximum applied current of DC 2 A

 

4-TERMINAL PROBE 9500-10

Cable length 1 m (3.28 ft), DC to 200 kHz, impedance characteristics of 50 Ω, measurable conductor diameter: φ0.3 mm (0.01 in) to 2 mm (0.08 in)

Hioki IM3536 LCR Meter

Measuring the Capacitance of Electrolytic Capacitors with Hioki LCR Meters

The measurement conditions under which the capacitance of electrolytic capacitors is defined are set forth by an IEC standard. However, since the capacitance of electrolytic capacitors varies significantly with the measurement frequency, capacitance values are also checked at the frequencies that correspond to the circuit conditions under which the components will actually be used. The LCR Meter IM3536’s measurement frequency can be set over a broad range of values (DC and 4 Hz to 8 MHz), making the instrument ideal for evaluating components under the conditions of actual use.

Measuring the Capacitance of Ceramic Capacitors with Hioki LCR Meters
There are two types of laminated ceramic capacitor: the high-dielectric type, whose capacitance varies with the measurement voltage, and the temperature-corrected type, whose capacitance does not vary. The measurement conditions under which capacitance is defined are set forth by separate IEC standards for the two types of component. The LCR Meter IM3536’s measurement frequency and measurement voltage can be set over a broad range of values (DC and 4 Hz to 8 MHz, and 10 mV to 5 V, respectively), making the instrument ideal for measuring laminated ceramic capacitors under a variety of conditions.

Measuring the Inductance of Inductors or Coils with HIOKI LCR Meters
The phenomenon of LC resonance based on the inductance of inductors (or coils) and the parasitic capacitance of coils is known as self-resonance, and the frequency at which self-resonance occurs is known as the self-resonant frequency. When evaluating a coil, measure L and Q at a frequency that is sufficiently lower than the self-resonant frequency. The LCR Meter IM3536’s measurement frequency can be set over a broad range of values (DC and 4 Hz to 8 MHz), making the instrument ideal for measuring and evaluating components while varying the frequency.

Measuring the Frequency Characteristics of Inductors on Hioki LCR Meters
The LCR Meter IM3536’s measurement frequency can be set over a broad range of values (DC and 4 Hz to 8 MHz), making it ideal for measuring and evaluating components while varying the frequency. You can install the included LCR sample application software (CD-R) on a computer and use it via the instrument’s interfaces (USB, GP-IB, or RS-232C) to vary the frequency at designated points and to save data obtained from automatic measurement as a Microsoft Excel or text file.

Additional information

Producent

Hioki

Produktkategori

LCR Meters

This website uses cookies. By continuing to use this site, you accept our use of cookies.  Learn more