Hioki MR8904 CAN Unit

Hioki MR8904 CAN Unit

Price on request

Analyse CAN singal module for Memory Recorders

Hioki MR8904 CAN Unit

Input CAN port Number of ports: 2, Connector: D-sub a male 9 pin ×2
Standards ISO 11898 CAN 2.0b, ISO 11898-1, ISO 11898-2, ISO 11898-3, SAE J2411
Interface Selectable: High-speed CAN, Low-speed CAN, or Single-wire CAN by port (with built-in corresponding transceiver)
Transmit ACK ON/OFF for transmitting a ACK for receiving CAN signal with the MR8904
Terminator ON/OFF via commands, 120 Ω ±10 Ω built-in resistance
Baud rate 50 kbps to 1 Mbps at “High-speed”, 10 kbps to 125 kbps at “Low-speed”, 10 kbps to 83.3 kbps at “Single-wire”
Analyzed signal output channel Up to 15 analog channels each equivalent to a 16-bit analog signal
Up to 16 logic channels each equivalent to a 1-bit logic signal
Signal form 1-bit signal: 1 channel of Logic, or 1 channel of Analog
1-bit to 16-bits signal: 1 channel of Analog
17-bits to 32-bits signal: 2 channels of Analog
* Cannot handle signals over 32-bits
ID trigger Output “H” level pulse to designated logic channel when receiving set ID signal
* Output pulse width: 50 μs below 5 ms/div time axis, 1 sampling time at more than 10 ms/div time axis
Response time Within 200 μs after completely receiving CAN message
Transmit CAN message Can transmit the setting CAN message to the CAN bus by a port
Dimensions and mass 119.5 mm (4.70 in)W × 18.8 mm (0.74 in)H × 151.5mm (5.96 in)D, 185 g (6.5 oz)
Accessories None

Additional information

Producent

Hioki

Produktkategori

Memory Recorder & Logger, Switching and Data Aquisition

This website uses cookies. By continuing to use this site, you accept our use of cookies.  Learn more