+45 31 33 18 19
salg@GOmeasure.dk

SIEPEL HERMES 10 Full Compliance 10 m EMC Chamber

SIEPEL HERMES 10 Full Compliance 10 m EMC Chamber

Price on request

OPTIONS

  • Other doors dimensions & types (single, double, sliding)
  • Electric or pneumatic assistance for door latching
  • Shielded control room, shielded amplifier room
  • Turntable (any diameter, any load)
  • Automatic antenna mast (1 to 4 m height scan)
  • GPIB interface controller (for positioners remote control)
  • Additional power filters, data filters and special connectors
  • Video monitoring CCTV system, Intercom/Audio monitoring system
  • Vinyl tiles on the floor
  • Plastic paint for pyramidal matched hybrid absorbers
  • Chamber testing
Category: Tag:

SIEPEL HERMES 10 Full Compliance 10 m EMC Chamber

STANDARDS

Radiated EMI testing fully compliant with the following standards, from 30 MHz to 18 GHz

  • CISPR 11
  • CISPR 16-1-4
  • CISPR 22
  • CISPR 32
  • EN 50147-2
  • EN 55011
  • EN 55022
  • ANSI C63.4

Radiated EMS testing fully compliant with:

  • IEC 61000-4-3 from 26 MHz to 18 GHz

Radio standards:

  • All ETSI standards referring to CISPR 16 and IEC 61000-4-3

BASIC CONFIGURATION

Shielded room 18030 x 12160 x 8440 mm (external shield to shield dimensions):

  • Structural steel frame and stiffeners
  • 1 manual, single leaf, “knife edge” shielded door, with clear opening 1500 x 2130 mm, including maintenance kit
  • Raised floor, with metallic ground plane and 2 access hatches
  • 4 honeycomb air vents 300 x 600 mm, fitted with flanges
  • 2 feedthrough panels 1220 x 200 mm fitted with 2 N connectors and 2 feedthrough waveguides Ø 20 mm for fibre optics
  • 1 power line filter 2 lines (single phase + neutral) – 32 A – 230 V – 50 Hz
  • Electrical package: 1 main switchboard with appropriate protection, electric distribution and lighting
  • Absorbers lining

EMI PERFORMANCES

SIEPEL HERMES 10 chamber is designed to perform full compliance radiated EMI testing according to the following standards: CISPR 11, CISPR 16, CISPR 22, CISPR 32, EN 50147-2, EN 55011, EN 55016, EN 55022, ANSI C63.4 from 30 MHz to 18 GHz.

As a basic design, we propose a test volume with following main features:

  • Diameter: 3 meters / Height: 2 meters
  • NSA (30 MHz – 1 GHz) max deviation from theoretical value: better than ± 4 dB
  • Site VSWR (1-18 GHz): ≤ 6 dB
  • For bigger EUTs, we can propose larger test volumes

EMS PERFORMANCES

SIEPEL HERMES 10 is fully compliant to perform radiated EMS testing according to the EN/IEC 61000-4-3, in the extended frequency range from 26 MHz to 18 GHz.

Immunity tests are performed with 16 electromagnetic pyramidal absorbers APM66 on the floor, between field generation antenna and uniform field plane.

Those absorbers can very easily be removed and stored outside the chamber, when they are not necessary.

SIEPEL HERMES 10 Full Compliance 10 m EMC Chamber

HERMES 10 V4

Additional information

Producent

Siepel

Produktkategori

Chambers

This website uses cookies. By continuing to use this site, you accept our use of cookies.  Learn more