Tektronix FCA3020 Frequency Counter

Tektronix FCA3020 Frequency Counter

Price on request

  • 20 GHz Model
  • 300-400 MHz in Manual Trigger Mode
  • Up to 3 Input Channels
  • 100 ps Single-shot Time Resolution
  • 12 Digit/s Frequency Resolution
  • 0.001° Phase Resolution
  • 3 mV or better Voltage Resolution
  • Optional 5×10–8 High-stability Oven Time Base
Categories: , Tag:

Tektronix FCA3020 Frequency Counter

The Tektronix FCA3020 offer many different functions into one feature-rich instrument. With unprecedented resolution, you can capture very small frequency and time changes. And with the industry’s most comprehensive analysis modes, including measurement statistics, histograms, and trend plots, you have the tools you need to quickly and accurately analyze your signal.

Feature-rich Tools for Precision Measurements

The FCA3000 and FCA3100 Timer/Counter/Analyzer Series pack many different functions into one feature-rich instrument. With industry-leading frequency and time resolution, the FCA Series comes standard with deep internal memory and a fast data transfer rate of 250k Samples/s to internal memory. In addition, the multi-parameter display shows auxiliary measurements alongside your main measurement to provide you with the results you need at a glance. With the industry’s most comprehensive analysis modes, including measurement statistics, histograms, and trend plots, you have the tools you need to quickly and accurately analyze your signal.

Industry-leading Performance for Demanding Designs

High-resolution is critical for R&D and production testing on today’s demanding designs. The FCA Series delivers 12-digit/s frequency resolution and for time measurements, single-shot resolution of 50 ps (FCA3100 Series) or 100 ps (FCA3000 Series) is available with measurement values displayed up to 14 digits. With industry-leading performance, the FCA Series provides you with fast, precise measurements.

Unique Features for Accurate Measurements

To ensure correct measurements of Allan Deviation, the FCA3100 Series offers a zero dead-time measurement technique and continuous time stamping of trigger events. This feature is vital for mechanical and medical measurements where every single cycle must be measured. The FCA3000 Series offers this functionality through the USB/GPIB interfaces with a raw time-stamping function.

For correct calculation of statistical parameters, the FCA Series comes standard with limit-qualifying capability. By setting limits, you can isolate one cluster in your calculation. This is important for applications such as verifying the jitter of digital pulses that appear in discrete clusters in CD players or in HDB3-coded data.

Also available is hysteresis compensation for time interval measurements. By adding hysteresis, you can reduce trigger-level error from the typical 15-20 mV found in most counters on the market today, down to a typical 2.5 mV. This means 6-8 times improved trigger precision in critical time interval measurements.

Fast Throughput Reduces Test Time

The FCA Timer/Counter/Analyzer Series offers industry-best throughput, saving you up to 90% on your testing time compared to other timer/counters on the market. Up to 250,000 measurement results per second can be stored in the internal memory. Alternatively, you can transfer up to 15,000 measurement results per second in Block mode through the GPIB or USB interface. For added flexibility, the FCA3100 Series offers a zero dead-time counter feature to continuously stream measurement data over the GPIB/USB bus during, not after, measurement. This creates a dynamic measurement and analysis system.

Analyze Your Device with the Industry’s Only Graphical Display

With the unique display of the FCA Series, you can measure multiple parameters of the same signal from one test connection. To reveal signal quality issues like drift, intermittent transients, and stability, you can view the data as a real-time trend plot or a histogram with the FCA Series graphical display mode, or you can use measurement statistics to track how signal parameters are changing over time. A single-button Analyze mode gives you fast insight into the behavior of your device right on the timer/counter’s display.

Features

Benefits

12 digit/s frequency resolution See small changes in frequency with industry-leading frequency resolution.
Down to 50 ps time resolution Accurately capture signal details with industry-leading single-shot time resolution.
Multi-parameter display Read critical auxiliary measurement values displayed with your main frequency, time, or phase measurement to quickly asses your device’s performance.
Trend Plot mode Plot measurement trends and graphically identify the extent of drift and intermittent events.
Histogram mode Discover stability or noise problems by viewing results as a histogram.
Statistics mode View multiple statistical values such as average, min, max, standard and Allan deviation to see how your signal is changing.
Optional TimeView™ software Transform your timer/counter into a modulation domain analyzer and see frequency changes over time to truly characterize your device’s performance.
USB and GPIB ports Easily connect to a personal computer for further analysis or into an ATE system with the back-panel USB and GPIB ports; an emulation mode for legacy timer/counters further simplifies integrating into an existing ATE system.
PC Connectivity Control your timer/counter, log data, and simply transfer and document your results with the included copy of NI LabVIEW SignalExpress software.

 

Tektronix FCA3020 Frequency Counter

FCA3000 + FCA3100 Datasheet

Tektronix FCA3020 Frequency Counter

Models

Model Description
FCA3000 Timer/Counter/Analyzer 300 MHz / 100 ps
FCA3003 Timer/Counter/Analyzer 3 GHz / 100 ps
FCA3020 Timer/Counter/Analyzer 20 GHz / 100 ps
FCA3100 Timer/Counter/Analyzer 300 MHz / 50 ps
FCA3103 Timer/Counter/Analyzer 3 GHz / 50 ps
FCA3120 Timer/Counter/Analyzer 20 GHz / 50 ps

FCA3000/3100 Series Include: Timer/Counter, line cord, calibration certificate, Quick Start User Manual, CD-ROM with user manual (English, French, German, Spanish, Simplified Chinese, Traditional Chinese, Korean, Russian, Japanese), Programmer’s Guide, Technical Specifications, Trial version of TimeView™ Software, and CD-ROM with National Instruments LabVIEW SignalExpress™ Tektronix Edition, Limited Edition Software.

Note: Please specify power plug when ordering.

Instrument Options

Option Description
MS Medium-stability Oven Time Base
HS High-stability Oven Time Base
RP Rear-panel Connectors