  • Analog Bandwidth : 350 MHz – 2 GHz
  • Sample Rate : 6.25 GS/s
  • Record Length : 62.5 M – 500 M
  • Analog Channels : 4
  • Digital Channels : Up to 32 (optional)
  • Function Generator Output : 1 (optional)
Categories: , Tag:

Tektronix MSO54B Oscilloscope

Never let a lack of channels slow down your verification and debug process again!

The Tektronix MSO54B offers better visibility into complex systems by offering four, six and eight channel models with a large 15.6- inch high-definition (1,920 x 1,080) display. Many applications, such as embedded systems, three-phase power electronics, automotive electronics, power supply design, and DC-to-DC power converters, require the observation of more than four analog signals to verify and characterize device performance, and to debug challenging system issues.

Most engineers can recall situations in which they were debugging a particularly difficult problem and wanted greater system visibility and context, but the scope they were using was limited to two or four analog channels. Using a second scope involves significant effort to align trigger points, difficulty in determining timing relationships across the two displays, and documentation challenges.

And while you might assume that a six and eight channel scope would cost 50% or 100% more than a four-channel scope, you’ll be pleasantly surprised to find that six channel models are only ~25% more than four channel models and eight channel models are only ~67% more than four channel models. The additional analog channels can pay for themselves quickly by enabling you to keep current and future projects on schedule.

FlexChannel® technology enables maximum flexibility and broader system visibility

The 5 Series MSO redefines what a Mixed Signal Oscilloscope (MSO) should be. FlexChannel technology enables each channel input to be used as a single analog channel, eight digital logic inputs (with the TLP058 logic probe), or simultaneous analog and spectrum views with independent acquisition controls for each domain. Imagine the flexibility and configurability this provides.

With an eight FlexChannel model, you can configure the instrument to look at eight analog and zero digital signals. Or seven analog and eight digital. Or six analog and 16 digital, five analog and 24 digital and so on. You can change the configuration at any time by simply adding or removing TLP058 logic probes, so you always have the right number of digital channels.

For more information: Tektronix

Tektronix MSO54B Oscilloscope

Tektronix MSO5B Series Datasheet

Tektronix MSO54B Oscilloscope

Ordering information

Use the following steps to select the appropriate instrument and options for your measurement needs.

Step 1
Start by selecting a 5 Series MSO model based on the number of FlexChannels you need
Model Number of FlexChannels
MSO54 4
MSO56 6
MSO58 8
Every 5 Series MSO includes
  • One passive probe per FlexChannel: TPP0500B (for models with 350 MHz or 500 MHz bandwidth) or TPP1000 (for models with 1 GHz or 2 GHz bandwidth)
  • Installation and safety manual (translated in English, Japanese, Simplified Chinese)
  • Integrated online help
  • Front cover with integrated accessory pouch
  • Mouse
  • Power cord
  • Calibration certificate documenting traceability to National Metrology Institute(s) and ISO9001 quality system registration
  • Three-year warranty covering all parts and labor on the 5 Series MSO instrument. One-year warranty covering all parts and labor on included probes
Step 2
Configure your oscilloscope by selecting the analog channel bandwidth you need
Choose the bandwidth you need today by choosing one of these bandwidth options. You can upgrade it later by purchasing an upgrade kit.

Bandwidth Option Bandwidth
5-BW-350 350 MHz
5-BW-500 500 MHz
5-BW-1000 1 GHz
5-BW-2000 2 GHz
Step 3
Add instrument functionality
Instrument functionality can be ordered with the instrument or later as an upgrade kit.

Instrument Option Built-in Functionality
5-RL-125 Extend record length to 125 Mpoints/channel
5-WIN Add removable SSD with Windows 10 license
5-AFG Add Arbitrary / Function Generator
Step 4
Add optional serial bus triggering, decode, and search capabilities
Choose the serial support you need today by choosing from these serial analysis options. You can upgrade later by purchasing an upgrade kit.

Instrument Option Serial Buses Supported
5-SRAUDIO Audio (I2S, LJ, RJ, TDM)
5-SRAUTO Automotive (CAN, LIN, FlexRay)
5-SRCOMP Computer (RS-232/422/485/UART)
5-SREMBD Embedded (I2C, SPI)
5-SRENET Ethernet (10BASE-T, 100BASE-TX)
5-SRUSB2 USB (USB2.0 LS, FS, HS 1 )
Differential serial bus? Be sure to check Step 7 for differential probes.

1USB high-speed supported only on models with ≥1 GHz bandwidth

Step 5
Add optional analysis capabilities
Instrument Option Advanced Analysis
5-DJA Advanced Jitter and Eye Analysis
Step 6
Add digital probes
Eight digital channels can be accessed on any FlexChannel simply by ordering a TLP058 logic probe, either with the instrument or separately.

For this instrument Order To access
MSO54 1 to 4 TLP058 Probes 8 to 32 digital channels
MSO56 1 to 6 TLP058 Probes 8 to 48 digital channels
MSO58 1 to 8 TLP058 Probes 8 to 64 digital channels
Step 7
Add additional recommended probes and adapters
Recommended Probe / Adapter Description
TLP058 8-channel general purpose logic probe. Includes accessory kit.
TAP1500 1.5 GHz TekVPI® active single-ended voltage probe, ±8 V differential input voltage
TAP2500 2.5 GHz TekVPI® active single-ended voltage probe, ±4 V differential input voltage
TCP0030A 30 A AC/DC TekVPI® current probe, 120 MHz BW
TCP0020 20 A AC/DC TekVPI® current probe, 50 MHz BW
TCP0150 150 A AC/DC TekVPI® current probe, 20 MHz BW
TRCP0300 30 MHz AC current probe, 250 mA to 300 A
TRCP0600 30 MHz AC current probe, 500 mA to 600 A
TRCP3000 16 MHz AC current probe, 500 mA to 3000 A
TDP0500 500 MHz TekVPI® differential voltage probe, ±42 V differential input voltage
TDP1000 1 GHz TekVPI® differential voltage probe, ±42 V differential input voltage
TDP1500 1.5 GHz TekVPI® differential voltage probe, ±8.5 V differential input voltage
TDP3500 3.5 GHz TekVPI® differential voltage probe, ±2 V differential input voltage
THDP0100 ±6 kV, 100 MHz TekVPI® high-voltage differential probe
THDP0200 ±1.5 kV, 200 MHz TekVPI® high-voltage differential probe
TMDP0200 ±750 V, 200 MHz TekVPI® high-voltage differential probe
TIVH02 Isolated Probe; 200 MHz, ±1000 V, TekVPI, 3 Meter Cable
TIVH02L Isolated Probe; 200 MHz, ±1000 V, TekVPI, 10 Meter Cable
TIVH05 Isolated Probe; 500 MHz, ±1000 V, TekVPI, 3 Meter Cable
TIVH05L Isolated Probe; 500 MHz, ±1000 V, TekVPI, 10 Meter Cable
TIVH08 Isolated Probe; 500 MHz, ±1000 V, TekVPI, 3 Meter Cable
TIVH08L Isolated Probe; 500 MHz, ±1000 V, TekVPI, 10 Meter Cable
TIVM1 Isolated Probe; 1 GHz, ±50 V, TekVPI, 3 Meter Cable
TIVM1L Isolated Probe; 1 GHz, ±50 V, TekVPI, 10 Meter Cable
TPP0502 500 MHz, 2X TekVPI® passive voltage probe, 12.7 pF input capacitance
TPP0850 2.5 kV, 800 MHz, 50X TekVPI® passive high-voltage probe
TPA-N-BNC 1 TekVPI® to TekProbe™ BNC adapter
TEK-DPG TekVPI deskew pulse generator signal source
067-1686-xx Power measurement deskew and calibration fixture
Looking for other probes? Check out the probe selector tool atwww.tek.com/probes.

1Recommended for connecting your existing TekProbe probes to the 5 Series MSO.

Step 8
Add traveling or mounting accessories
Optional Accessory Description
HC5 Hard carrying case
RM5 Rackmount kit
Step 9
Select power cord option
Power Cord Option Description
A0 North America power plug (115 V, 60 Hz)
A1 Universal Euro power plug (220 V, 50 Hz)
A2 United Kingdom power plug (240 V, 50 Hz)
A3 Australia power plug (240 V, 50 Hz)
A5 Switzerland power plug (220 V, 50 Hz)
A6 Japan power plug (100 V, 50/60 Hz)
A10 China power plug (50 Hz)
A11 India power plug (50 Hz)
A12 Brazil power plug (60 Hz)
A99 No power cord
Step 10
Add extended service and calibration
Service Option Description
T3 Three Year Total Protection Plan, includes repair or replacement coverage from wear and tear, accidental damage, ESD or EOS plus preventive maintenance. Includes 5-day turnaround time and priority access to customer support.
T5 Five Year Total Protection Plan, includes repair or replacement coverage from wear and tear, accidental damage, ESD or EOS plus preventive maintenance. Includes 5-day turnaround time and priority access to customer support.
R5 Standard Warranty Extended to 5 Years. Covers parts, labor and 2-day shipping within country. Guarantees faster repair time than without coverage. All repairs include calibration and updates. Hassle free – a single call starts the process.
C3 Calibration service 3 Years. Includes traceable calibration or functional verification where applicable, for recommended calibrations. Coverage includes the initial calibration plus 2 years calibration coverage.
C5 Calibration service 5 Years. Includes traceable calibration or functional verification where applicable, for recommended calibrations. Coverage includes the initial calibration plus 4 years calibration coverage.
D1 Calibration Data Report
D3 Calibration Data Report 3 Years (with Option C3)
D5 Calibration Data Report 5 Years (with Option C5)