+45 31 33 18 19
salg@GOmeasure.dk

Tektronix MSO68B Oscilloscope

Tektronix MSO68B Oscilloscope

Price on request

  • Analog Bandwidth: 1 GHz – 10 GHz
  • Sample Rate: Up to 50 GS/s
  • Record Length: 62.5 M – 1 G
  • Analog Channels: 8
  • Digital Channels: Up to 32 (optional)
  • Function Generator Output: 1 (optional)
Categories: , Tag:

Tektronix MSO68B Oscilloscope

The Tektronix MSO68B is a oscilloscope from the MSO 6 Series B. The Tektronix MSO68B has 8 channels and a bandwidth from 1 to 10 GHz.

With the lowest input noise and up to 10 GHz analog bandwidth, the 6 Series MSO provides the best signal fidelity for analyzing and debugging today’s embedded systems with GHz clock and bus speeds. The remarkably innovative pinch-swipe-zoom touchscreen user interface coupled with the industry’s largest high definition display and up to 8 FlexChannel® inputs that let you measure one analog or eight digital signals per channel, the 6 Series MSO is ready for today’s toughest challenges and tomorrow’s too.

Never let a lack of channels slow down your verification and debug process again

The 6 Series MSO offers better visibility into complex systems by offering four, six and eight-channel models with a large 15.6-inch high-definition (1,920 x 1,080) display. Many applications, such as embedded systems, three-phase power electronics, automotive electronics, power supply design, and Power Integrity require the observation of more than four analog signals to verify and characterize device performance and to debug challenging system issues.

Most engineers can recall situations in which they were debugging a particularly difficult problem and wanted greater system visibility and context, but the oscilloscope they were using was limited to two or four analog channels. Using a second oscilloscope involves significant effort to align the trigger points, difficulty in determining the timing relationships across the two displays, and documentation challenges.

You might assume that a six and eight-channel oscilloscope would cost 50% or 100% more than a four-channel oscilloscope, you’ll be pleasantly surprised to find that six-channel models are only ~25% more than four channel models and eight-channel models are only ~67% (or less) more than four channel models. The additional analog channels can pay for themselves quickly by enabling you to keep current and future projects on schedule.

FlexChannel® technology enables maximum flexibility and broader system visibility

The 6 Series MSO redefines what a Mixed Signal Oscilloscope (MSO) should be. FlexChannel technology enables each channel input to be used as a single analog channel, eight digital logic inputs (with the TLP058 logic probe), or simultaneous analog and spectrum views with independent acquisition controls for each domain. Imagine the flexibility and configurability this provides.

You can change the configuration at any time by simply adding or removing TLP058 logic probes, so you always have the right number of digital channels.

FlexChannel technology enables the ultimate in flexibility. Each input can be configured as a single analog or eight digital channels based on the type of probe you attach.

Previous-generation MSOs required tradeoffs, with digital channels having lower sample rates or shorter record lengths than analog channels. The 6 Series MSO offers a new level of integration of digital channels. Digital channels share the same high sample rate (up to 50 GS/s), and long record length (up to 1Gpoints) as analog channels.

The TLP058 provides eight high performance digital inputs. Connect as many TLP058 probes as you like, enabling up to a maximum of 64 digital channels.

Channel 2 has a TLP058 Logic Probe connected to the eight inputs of a DAC. Notice the green and blue color coding, where ones are green and zeros are blue. Another TLP058 Logic Probe on Channel 3 is probing the SPI bus driving the DAC. The white edges indicate higher frequency information is available by either zooming in or moving to a faster sweep speed on the next acquisition.

Beyond just analog and digital, FlexChannel inputs include Spectrum View. This Tektronix-patented technology enables you to simultaneously view both analog and spectral views of all your analog signals, with independent controls in each domain. For the first time ever, oscilloscope-based frequency-domain analysis is as easy as using a spectrum analyzer while retaining the ability to correlate frequency-domain activity with other time-domain phenomena.

Unprecedented signal viewing capability

The stunning 15.6″ (396 mm) display in the 6 Series MSO is the largest display in the industry. It is also the highest resolution display, with full HD resolution (1,920 x 1,080), enabling you to see many signals at once with ample room for critical readouts and analysis.

The viewing area is optimized to ensure that the maximum vertical space is available for waveforms. The Results Bar on the right can be hidden, enabling the waveform view to use the full width of the display.

Stacked display mode enables easy visibility of all waveforms while maintaining maximum ADC resolution on each input for the most accurate measurements.

The 6 Series MSO offers a revolutionary new Stacked display mode. Historically, scopes have overlaid all waveforms in the same graticule, forcing difficult tradeoffs:

  • To make each waveform visible, you vertically scale and position each waveform so that they don’t overlap. Each waveform uses a small percentage of the available ADC range, leading to less accurate measurements.
  • For measurement accuracy, you vertically scale and position each waveform to cover the entire display. The waveforms overlap each other, making it hard to distinguish signal details on individual waveforms

The new Stacked display eliminates this tradeoff. It automatically adds and removes additional horizontal waveform ‘slices’ (additional graticules) as waveforms are created and removed. Each slice represents the full ADC range for the waveform.

All waveforms are visually separated from each other while still using the full ADC range, enabling maximum visibility and accuracy. And it’s all done automatically as waveforms are added or removed! Channels can easily be reordered in stacked display mode by dragging and dropping the channel and waveform badges in the Settings bar at the bottom of the display. Groups of channels can also be overlaid within a slice to simplify visual comparison of signals.

The massive display in the 6 Series MSO also provides plenty of viewing area not only for signals, but also for plots, measurement results tables, bus decode tables and more. You can easily resize and relocate the various views to suit your application.

Viewing three analog channels, eight digital channels, a decoded serial bus waveform, decoded serial packet results table, four measurements, a measurement histogram, measurements results table with statistics and a search on serial bus events – simultaneously!

Exceptionally easy-to-use user interface lets you focus on the task at hand

The Settings Bar – key parameters and waveform management

Waveform and scope operating parameters are displayed in a series of “badges” in the Settings Bar that runs along the bottom of the display. The Settings Bar provides Immediate access for the most common waveform management tasks. With a single tap, you can:

  • Turn on channels
  • Add math waveforms
  • Add reference waveforms
  • Add bus waveforms
  • Enable the optional integrated Arbitrary/Function generator (AFG)
  • Enable the optional integrated digital voltmeter (DVM)

The Results Bar – analysis and measurements

The Results Bar on the right side of the display includes immediate, one-tap access to the most common analytical tools such as cursors, measurements, searches, measurement and bus decode results tables, plots, and callouts.

DVM, measurement and search results badges are displayed in the Results Bar without sacrificing any waveform viewing area. For additional waveform viewing area, the Results Bar can be dismissed and brought back at any time.

Configuration menus are accessed by simply double-tapping on the item of interest on the display. In this case, the Trigger badge was double-tapped to open the Trigger configuration menu.

Touch interaction finally done right

Scopes have included touch screens for years, but the touch interface has been an afterthought. The 6 Series MSO’s 15.6″ display includes a capacitive touchscreen and provides the industry’s first oscilloscope user interface truly designed for touch.

The touch interactions that you use with phones and tablets, and expect in a touch enabled device, are supported in the 6 Series MSO.

  • Drag waveforms left/right or up/down to adjust horizontal and vertical position or to pan a zoomed view
  • Pinch and expand to change scale or zoom in/out in either horizontal or vertical directions
  • Flick items off the edge of the screen to delete them
  • Swipe in from the right to reveal the Results Bar or down from the top to access the menus in the upper left corner of the display

Smooth, responsive front panel controls allow you to make adjustments with familiar knobs and buttons, and you can add a mouse or keyboard as a third interaction method.

Interact with the capacitive touch display in the same way you do on your phones and tablets.

Variable font size

Historically, oscilloscope user interfaces have been designed with fixed font sizes to optimize viewing of waveforms and readouts. This implementation is fine if all users have the same viewing preferences, but they don’t.

Users spend a significant amount of time staring at screens, and Tektronix recognizes this. The 6 Series MSO offers a user preference for variable font sizes; scaling down to 12 points or up to 20 points. As you adjust the font size, the user interface dynamically scales so you can easily choose the best size for your application.

For more information: Tektronix

Tektronix MSO68B Oscilloscope

Tektronix MSO6B Datasheet

Tektronix MSO68B Oscilloscope

Ordering information

Use the following steps to select the appropriate instrument and options for your measurement needs.

Step 1
Start by selecting the model.
Model Number of FlexChannels
MSO64B 4
MSO66B 6
MSO68B 8
Each model includes
One TPP1000 1 GHz probe per FlexChannel
Installation and safety manual (translated in English, Japanese, Simplified Chinese)
Embedded Help
Front cover with integrated accessory pouch
Mouse
Power cord
Calibration certificate documenting traceability to National Metrology Institute(s) and ISO9001/ISO17025 quality system registration
One-year warranty covering all parts and labor on the instrument.
One-year warranty covering all parts and labor on included probes
Step 2
Configure your oscilloscope by selecting the analog channel bandwidth you need
Choose the bandwidth you need today by choosing one of these bandwidth options. You can upgrade it later by purchasing an upgrade option.

Bandwidth Option Bandwidth
6-BW-1000 1 GHz
6-BW-2500 2.5 GHz
6-BW-4000 4 GHz
6-BW-6000 6 GHz
6-BW-8000 8 GHz
6-BW-10000 10 GHz

Note: For instruments of 4, 6, 8 or 10 GHz bandwidth, consider a BNC-to-SMA adapter to optimize a high bandwidth connection to the oscilloscope. Tektronix part number 103-0503-XX.

Step 3
Add instrument functionality
Instrument functionality can be ordered with the instrument or later as an upgrade kit.

Instrument Option Built-in Functionality
6-RL-1 Extend record length from 62.5 Mpoints/channel to 125 Mpoints/channel
6-RL-2 Extend record length from 62.5 Mpts/channel to 250 Mpts/channel
6-RL-3 Extend record length from 62.5 Mpoints/channel to 500 Mpoints/channel
6-RL-4 Extend record length from 62.5 Mpoints/channel to 1 Gpoints/channel
6-AFG Add Arbitrary / Function Generator
6-SEC 1 Add enhanced security for instrument declassification and password-protected enabling and disabling of all USB ports and firmware upgrade.
6-WIN Add removable SSD with Microsoft Windows 10 operating system license

1This option must be purchased at the same time as the instrument. Not available as an upgrade.

Step 4
Add optional serial bus triggering, decode, and search capabilities
Choose the serial support you need today by choosing from these serial analysis options. You can upgrade later by purchasing an upgrade kit.

Instrument Option Serial Buses Supported
6-SRAERO Aerospace (MIL-STD-1553, ARINC 429)
6-SRAUDIO Audio (I2S, LJ, RJ, TDM)
6-SRAUTO Automotive (CAN, CAN FD, LIN, FlexRay, and CAN symbolic decoding)
6-SRAUTOEN1 100BASE-T1 Automotive Ethernet serial analysis
6-SRAUTOSEN Automotive sensor (SENT)
6-SRCOMP Computer (RS-232/422/485/UART)
6-SRDPHY MIPI D-PHY (DSI-1, CSI-2 decode and search only)
6-SREMBD Embedded (I2C, SPI)
6-SRENET Ethernet (10BASE-T, 100BASE-TX)
6-SR8B10B 8B/10B(decode and search only)
6-SRI3C MIPI I3C (I3C decode and search only)
6-SRMANCH Manchester (decode and search only)
6-SRMDIO MDIO (decode and search only)
6-SRNRZ NRZ (decode and search only)
6-SRPM Power Management (SPMI)
6-SRPSI5 PSI5 (decode and search only)
6-SRSPACEWIRE Spacewire (decode and search only)
6-SRSVID SVID (decode and search only)
6-SRUSB2 USB (USB2.0 LS, FS, HS)
6-SREUSB2 eUSB2.0 (decode and search only)
Differential serial bus? Be sure to checkAdd analog probes and adapters for differential probes.
Add third party serial bus decode and analysis capabilities
Third-party applications are available that provide serial bus decode and analysis capabilities for use on the 6 Series B MSO. Tektronix part numbers listed below can be ordered directly from Tektronix or through an authorized distributor. Ordered application software will be shipped directly by the third-party. Use of the third-party software applications require a Windows 10 SSD (option 6-WIN).

Tektronix Part Number Serial Buses Supported
PGY-EMMC Embedded Multi-media Controller (eMMC) memory
PGY-QSPI Quad Serial Peripheral Interface (QSPI) – 2 enhanced IO lines for SPI
PGY-SDIO Secure Digital Input Output (SDIO)
Step 5
Add optional serial bus compliance testing
Choose the serial compliance testing packages you need today by choosing from these options. You can upgrade later by purchasing an upgrade kit. All options in the table below require option 6-WIN (SSD with Microsoft Windows 10 operating system).

Instrument Option Serial Buses Supported
6-CMAUTOEN Automotive Ethernet (100Base-T1, 1000Base-T1) automated compliance test solution.
≥2 GHz bandwidth required for 1000BASE-T1
6-CMAUTOEN10 Automotive Ethernet (10BASE-T1S Short Reach) automated compliance test solution.
6-AUTOEN-BND Automotive Ethernet Compliance, Signal Separation, PAM3 Analysis, 100Base-T1 Decode software (requires options 6-DJA and 6-WIN)
6-AUTOEN-SS Automotive Ethernet Signal Separation
6-CMINDUEN10 Industrial Ethernet (10Base-T1L Long Reach) automated compliance test solution
6-CMDPHY MIPI D-DPHY 1.2 automated compliance test solution.
6-CMENET Ethernet automated compliance test solution (10BASE-T/100BASE-T/1000BASE-T).
≥1 GHz bandwidth required for 1000BASE-T
6-CMNBASET 2.5 and 5 GBASE-T Ethernet automated compliance test solution.
2.5 GHz is recommended
6-CMXGBT 10 GBASE-T Ethernet automated compliance test solution.
≥4 GHz is recommended
6-CMUSB2 USB2.0 automated compliance test solution.
Requires TDSUSBF USB test fixture
≥2 GHz bandwidth required for high-speed USB
Step 6
Add optional memory analysis
Instrument Option Advanced Analysis
6-DBDDR3 DDR3 and LPDDR3 Debug and Analysis
6-CMDDR3 DDR3 and LPDDR3 automated compliance test solution using TekExpress Automation Platform.
Requires options 6-DBDDR3, 6-DJA and 6-WIN (SSD with Microsoft Windows 10 operating system).
≥4 GHz required, 8 GHz recommended for testing of all DDR3 speeds.
Step 7
Add optional analysis capabilities
Instrument Option Advanced Analysis
6-DBLVDS TekExpress automated LVDS test solution (requires options 6-DJA and 6-WIN)
6-DJA Advanced Jitter and Eye Analysis
6-DPM Digital Power Management
6-IMDA 1 Inverter motor drive analysis
6-IMDA-DQ0 1 DQ0 feature for inverter motor drive analysis
6-MTM Mask and Limit testing
6-PAM3 PAM3 Analysis (requires options 6-DJA and 6-WIN)
6-PS2 2 Power solution bundle (6-PWR, THDP0200, TCP0030A, 067-1686-XX deskew fixture)
6-PWR 3 Power Measurement and Analysis
6-SV-BW-1 Increase Spectrum View Capture Bandwidth to 2 GHz
6-SV-RFVT Spectrum View RF versus Time analysis and remote IQ data transferring
6-VID NTSC, PAL, and SECAM video triggering

1This option is not compatible with MSO64B.

2This option is not compatible with option 6-PWR.

3This option is not compatible with option 6-PS2.

Step 8
Add digital probes
Each FlexChannel input can be configured as eight digital channels simply by connecting a TLP058 logic probe.

For this instrument Order To add
MSO64B 1 to 4 TLP058 Probes 8 to 32 digital channels
MSO66B 1 to 6 TLP058 Probes 8 to 48 digital channels
MSO68B 1 to 8 TLP058 Probes 8 to 64 digital channels
Step 9
Add analog probes and adapters
Add additional recommended probes and adapters

Recommended Probe / Adapter Description
TAP1500 1.5 GHz TekVPI® active single-ended voltage probe, ±8 V input voltage
TAP2500 2.5 GHz TekVPI® active single-ended voltage probe, ±4 V input voltage
TAP3500 3.5 GHz TekVPI® active single-ended voltage probe, ±4 V input voltage
TAP4000 4 GHz TekVPI® active single-ended voltage probe, ±4 V input voltage
TCP0020 20 A AC/DC TekVPI® current probe, 50 MHz BW
TCP0030A 30 A AC/DC TekVPI current probe, 120 MHz BW
TCP0150 150 A AC/DC TekVPI® current probe, 20 MHz BW
TCPA300 100 MHz Current Probe, Amplifier (Requires Probe); Recommend using TPA-BNC adapter to provide autoscaling.
TCP312A DC-100 MHz, AC/DC Current Probe; 30 Amp DC
TRCP0300 30 MHz AC current probe, 250 mA to 300 A
TRCP0600 30 MHz AC current probe, 500 mA to 600 A
TRCP3000 16 MHz AC current probe, 500 mA to 3000 A
TDP0500 500 MHz TekVPI® differential voltage probe, ±42 V differential input voltage
TDP1000 1 GHz TekVPI® differential voltage probe, ±42 V differential input voltage
TDP1500 1.5 GHz TekVPI® differential voltage probe, ±8.5 V differential input voltage
TDP3500 3.5 GHz TekVPI® differential voltage probe, ±2 V differential input voltage
TDP4000 4 GHz TekVPI® differential voltage probe, ±2 V differential input voltage
TDP7704 4 GHz TriMode™ voltage probe
TDP7706 6 GHz TriMode™ voltage probe
TDP7708 8 GHz TriMode™ voltage probe
THDP0100 ±6 kV, 100 MHz TekVPI® high-voltage differential probe
THDP0200 ±1.5 kV, 200 MHz TekVPI® high-voltage differential probe
TMDP0200 ±750 V, 200 MHz TekVPI® high-voltage differential probe
TPR1000 1 GHz, Single-Ended TekVPI® Power-Rail Probe; includes one TPR4KIT accessory kit
TPR4000 4 GHz, Single-Ended TekVPI® Power-Rail Probe; includes one TPR4KIT accessory kit
TIVH02 Isolated Probe; 200 MHz, ±2500 V, TekVPI, 3 Meter Cable
TIVH02L Isolated Probe; 200 MHz, ±2500 V, TekVPI, 10 Meter Cable
TIVH05 Isolated Probe; 500 MHz, ±2500 V, TekVPI, 3 Meter Cable
TIVH05L Isolated Probe; 500 MHz, ±2500 V, TekVPI, 10 Meter Cable
TIVH08 Isolated Probe; 800 MHz, ±2500 V, TekVPI, 3 Meter Cable
TIVH08L Isolated Probe; 800 MHz, ±2500 V, TekVPI, 10 Meter Cable
TIVM1 Isolated Probe; 1 GHz, ±50 V, TekVPI, 3 Meter Cable
TIVM1L Isolated Probe; 1 GHz, ±50 V, TekVPI, 10 Meter Cable
TPP0502 500 MHz, 2X TekVPI® passive voltage probe, 12.7 pF input capacitance
TPP0850 2.5 kV, 800 MHz, 50X TekVPI® passive high-voltage probe
P6015A 20 kV, 75 MHz high-voltage passive probe
TPA-BNC 1 TekVPI® to TekProbe™ BNC adapter
103-0503-xx BNC-to-SMA adapter; rated to 12 GHz
TEK-DPG TekVPI deskew pulse generator signal source
067-1686-xx Power measurement deskew and calibration fixture
Looking for other probes? Check out the probe selector tool atwww.tek.com/probes.

1Recommended for connecting your existing TekProbe probes to the 6 Series MSO.

Step 10
Add accessories
Add traveling or mounting accessories

Optional Accessory Description
HC5 Hard carrying case
RM5 Rackmount kit
GPIB to Ethernet adapter Order model 4865B (GPIB to Ethernet to Instrument Interface) directly from ICS Electronics
www.icselect.com/gpib_instrument_intfc.html
Step 11
Select power cord option
Power Cord Option Description
A0 North America power plug (115 V, 60 Hz)
A1 Universal Euro power plug (220 V, 50 Hz)
A2 United Kingdom power plug (240 V, 50 Hz)
A3 Australia power plug (240 V, 50 Hz)
A5 Switzerland power plug (220 V, 50 Hz)
A6 Japan power plug (100 V, 50/60 Hz)
A10 China power plug (50 Hz)
A11 India power plug (50 Hz)
A12 Brazil power plug (60 Hz)
A99 No power cord
Step 12
Add extended service and calibration options
Service Option Description
T3 Three Year Total Protection Plan, includes repair or replacement coverage from wear and tear, accidental damage, ESD or EOS.
T5 Five Year Total Protection Plan, includes repair or replacement coverage from wear and tear, accidental damage, ESD or EOS.
R3 Standard Warranty Extended to 3 Years. Covers parts, labor and 2-day shipping within country. Guarantees faster repair time than without coverage. All repairs include calibration and updates. Hassle free – a single call starts the process.
R5 Standard Warranty Extended to 5 Years. Covers parts, labor and 2-day shipping within country. Guarantees faster repair time than without coverage. All repairs include calibration and updates. Hassle free – a single call starts the process.
C3 Calibration service 3 Years. Includes traceable calibration or functional verification where applicable, for recommended calibrations. Coverage includes the initial calibration plus 2 years calibration coverage.
C5 Calibration service 5 Years. Includes traceable calibration or functional verification where applicable, for recommended calibrations. Coverage includes the initial calibration plus 4 years calibration coverage.
D1 Calibration Data Report
D3 Calibration Data Report 3 Years (with Option C3)
D5 Calibration Data Report 5 Years (with Option C5)
Feature upgrades after purchase
Add feature upgrades in the future
The 6 Series products offer many ways to easily add functionality after the initial purchase. Node-locked licenses permanently enable optional features on a single product. Floating licenses allow license-enabled options to be easily moved between compatible instruments.

Upgrade feature Node-locked license upgrade Floating license upgrade Description
Add instrument functions SUP6-AFG SUP6-AFG-FL Add arbitrary function generator
SUP6-RL-1 SUP6-RL-1-FL Extend record length from 62.5 Mpts to 125 Mpts / channel
SUP6-RL-2 SUP6-RL-2-FL Extend record length from 62.5 Mpts to 250 Mpts / channel
SUP6-RL-3 SUP6-RL-3-FL Extend record length from 62.5 Mpts to 500 Mpts / channel
SUP6-RL-4 SUP6-RL-4-FL Extend record length from 62.5 Mpts to 1 Gpts / channel
SUP6-RL-1T2 SUP6-RL-1T2-FL Extend record length from 125 Mpts to 250 Mpts / channel
SUP6-RL-1T3 SUP6-RL-1T3-FL Extend record length from 125 Mpts to 500 Mpts / channel
SUP6-RL-1T4 SUP6-RL-1T4-FL Extend record length from 125 Mpts to 1 Gpts / channel
SUP6-RL-2T3 SUP6-RL-2T3-FL Extend record length from 250 Mpts to 500 Mpts / channel
SUP6-RL-2T4 SUP6-RL-2T4-FL Extend record length from 250 Mpts to 1 Gpts / channel
SUP6-RL-3T4 SUP6-RL-3T4-FL Extend record length from 500 Mpts to 1 Gpts / channel
Add protocol analysis SUP6-SRAERO SUP6-SRAERO-FL Aerospace serial triggering and analysis (MIL-STD-1553, ARINC 429)
SUP6-SRAUDIO SUP6-SRAUDIO-FL Audio serial triggering and analysis (I2S, LJ, RJ, TDM)
SUP6-SRAUTO SUP6-SRAUTO-FL Automotive serial triggering and analysis (CAN, CAN FD, LIN, FlexRay, and CAN symbolic decoding)
SUP6-SRAUTOEN1 SUP6-SRAUTOEN1-FL 100Base-T1 Automotive Ethernet serial analysis
SUP6-SRAUTOSEN SUP6-SRAUTOSEN-FL Automotive sensor serial triggering and analysis (SENT)
SUP6-SRCOMP SUP6-SRCOMP-FL Computer serial triggering and analysis (RS-232/422/485/UART)
SUP6-SRDPHY SUP6-SRDPHY-FL MIPI D-PHY serial analysis (DSI-1, CSI-2)
SUP6-SREMBD SUP6-SREMBD-FL Embedded serial triggering and analysis (I2C, SPI)
SUP6-SRENET SUP6-SRENET-FL Ethernet serial triggering and analysis (10Base-T, 100Base-TX)
SUP6-SREUSB2 SUP6-SRESUB2-FL Embedded USB2 (eUSB2) serial decoding and analysis
SUP6-SRI3C SUP6-SRI3C-FL MIPI I3C serial decoding and analysis
SUP6-SRMANCH SUP6-SRMANCH-FL Manchester serial analysis
SUP6-SRMDIO SUP6-SRMDIO-FL Management Data Input/Output (MDIO) serial decoding and analysis
SUP6-SR8B10B SUP6-SR8B10B-FL 8b/10b serial decoding and analysis
SUP6-SRNRZ SUP6-SRNRZ-FL NRZ serial decoding and analysis
SUP6-SRPM SUP6-SRPM-FL Power Management serial triggering and analysis (SPMI)
SUP6-SRPSI5 SUP6-SRPSI5-FL PSI5 serial decoding and analysis
SUP6-SRSPACEWIRE SUP6-SRSPACEWIRE-FL Spacewire serial analysis
SUP6-SRSVID SUP6-SRSVID-FL Serial Voltage Identification (SVID) serial decoding and analysis
SUP6-SRUSB2 SUP6-SRUSB2-FL USB 2.0 serial bus triggering and analysis (LS, FS, HS)
Add serial compliance

All serial compliance products require option 6-WIN (SSD with Microsoft Windows 10 operating system)

SUP6-CMAUTOEN SUP6-CMAUTOEN-FL Automotive Ethernet automated compliance test solution (100BASE-T1 and 1000BASE-T1)
SUP6-CMAUTOEN10 SUP6-CMAUTOEN10-FL Automotive Ethernet (10BASE-T1S Short Reach) automated compliance test solution
SUP6-AUTOEN-BND Automotive Ethernet compliance, signal separation, PAM3 analysis, 100Base-T1 serial analysis (requires options 6-DJA and 6-WIN)
SUP6-AUTOEN-SS SUP6-AUTOEN-SS-FL Automotive Ethernet signal separation
SUP6-CMINDUEN10 SUP6-CMINDUEN10-FL Industrial Ethernet (10Base-T1L Long Reach) automated compliance test solution
SUP6-CMDPHY SUP6-CMDPHY-FL MIPI D-PHY 1.2 automated compliance test solution
SUP6-CMENET SUP6-CMENET-FL Ethernet automated compliance test solution (10BASE-T, 100BASE-T, and 1000BASE-T) Requires SSD with Microsoft Windows 10 operating system
SUP6-CMNBASET SUP6-CMNBASET-FL 2.5 and 5 GBASE-T Ethernet automated compliance test (2.5 GHz is recommended)
SUP6-CMUSB2 SUP6-CMUSB2-FL USB 2.0 automated compliance test solution
Add advanced analysis SUP6-DBLVDS SUP6-DBLVDS-FL LVDS debug and analysis (requires options 6-DJA and 6-WIN)
SUP6-DJA SUP6-DJA-FL Advanced jitter and eye analysis
SUP6-DPM SUP6-DPM-FL Digital power management
SUP6-MTM SUP6-MTM-FL Mask and Limit testing
SUP6-PAM3 SUP6-PAM3-FL PAM3 analysis (requires options 6-DJA and 6-WIN)
SUP6-PS2 N/A Power solution bundle (6-PWR, THDP0200, TCP0030A, and 067-1686-XX deskew fixture)
SUP6-PWR SUP6-PWR-FL Advanced power measurements and analysis
SUP6-SV-BW-1 SUP6-SV-BW-1-FL Increase Spectrum View capture bandwidth to 2 GHz
SUP6-SV-RFVT SUP6-SV-RFVT-FL Spectrum View RF versus time analysis and trigger
SUP6-VID SUP6-VID-FL NTSC, PAL, and SECAM video triggering
SUP6B-IMDA SUP6B-IMDA-FL Inverter Motor Drive analysis
SUP6B-IMDA-DQ0 SUP6B-IMDA-DQ0-FL DQ0 Feature for Inverter Motor Drive analysis
Add memory analysis SUP6-DBDDR3 SUP6-DBDDR3-FL DDR3 and LPDDR3 debug and analysis
SUP6-CMDDR3 SUP6-CMDDR3-FL DDR3 and LPDDR3 automated compliance test solution using TekExpress Automation Platform.
Requires options 6-DBDDR3, 6-DJA and SSD with Microsoft WIndows 10 operating system.
≥4 GHz required, 8 GHz recommended for testing of all DDR3 speeds.
Add digital voltmeter SUP6-DVM N/A Add digital voltmeter / trigger frequency counter (Free with product registration at www.tek.com/register6mso)

 

Upgrade feature Upgrade Description
Add expansion Windows operating system SSD SUP6B-WIN Add removable SSD with Windows 10 operating system
Add expansion embedded operating system SSD SUP6B-LNX Add removable SSD with embedded operating system
Bandwidth upgrades after purchase
Add bandwidth upgrades in the future
The analog bandwidth of 6 Series products can be upgraded after initial purchase. Bandwidth upgrades are purchased based on the number of FlexChannels, the current bandwidth and the desired bandwidth. All bandwidth upgrades can be performed in the field by installing a software license and a new front panel label.

A calibration data report can also be purchased with the bandwidth upgrade. (Purchase SUP6B-BWx-DATA with option D1, where ‘x’ is either 4, 6, or 8 depending on the number of FlexChannels on your instrument.)

Oscilloscope model owned Bandwidth upgrade product Upgrade option Upgrade option description
MSO64B SUP6B-BW4 6B-BW10T25-4 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 1 GHz to 2.5 GHz bandwidth on a (4) FlexChannel model
6B-BW10T40-4 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 1 GHz to 4 GHz bandwidth on a (4) FlexChannel model
6B-BW10T60-4 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 1 GHz to 6 GHz bandwidth on a (4) FlexChannel model
6B-BW10T80-4 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 1 GHz to 8 GHz bandwidth on a (4) FlexChannel model
6B-BW10T100-4 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 1 GHz to 10 GHz bandwidth on a (4) FlexChannel model
6B-BW25T40-4 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 2.5 GHz to 4 GHz bandwidth on a (4) FlexChannel model
6B-BW25T60-4 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 2.5 GHz to 6 GHz bandwidth on a (4) FlexChannel model
6B-BW25T80-4 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 2.5 GHz to 8 GHz bandwidth on a (4) FlexChannel model
6B-BW25T100-4 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 2.5 GHz to 10 GHz bandwidth on a (4) FlexChannel model
6B-BW40T60-4 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 4 GHz to 6 GHz bandwidth on a (4) FlexChannel model
6B-BW40T80-4 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 4 GHz to 8 GHz bandwidth on a (4) FlexChannel model
6B-BW40T100-4 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 4 GHz to 10 GHz bandwidth on a (4) FlexChannel model
6B-BW60T80-4 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 6 GHz to 8 GHz bandwidth on a (4) FlexChannel model
6B-BW60T100-4 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 6 GHz to 10 GHz bandwidth on a (4) FlexChannel model
6B-BW80T100-4 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 8 GHz to 10 GHz bandwidth on a (4) FlexChannel model
MSO66B SUP6B-BW6 6B-BW10T25-6 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 1 GHz to 2.5 GHz bandwidth on a (6) FlexChannel model
6B-BW10T40-6 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 1 GHz to 4 GHz bandwidth on a (6) FlexChannel model
6B- BW10T60-6 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 1 GHz to 6 GHz bandwidth on a (6) FlexChannel model
6B-BW10T80-6 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 1 GHz to 8 GHz bandwidth on a (6) FlexChannel model
6B-BW10T100-6 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 1 GHz to 10 GHz bandwidth on a (6) FlexChannel model
6B-BW25T40-6 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 2.5 GHz to 4 GHz bandwidth on a (6) FlexChannel model
6B-BW25T60-6 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 2.5 GHz to 6 GHz bandwidth on a (6) FlexChannel model
6B-BW25T80-6 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 2.5 GHz to 8 GHz bandwidth on a (6) FlexChannel model
6B-BW25T100-6 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 2.5 GHz to 10 GHz bandwidth on a (6) FlexChannel model
6B-BW40T60-6 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 4 GHz to 6 GHz bandwidth on a (6) FlexChannel model
6B-BW40T80-6 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 4 GHz to 8 GHz bandwidth on a (6) FlexChannel model
6B-BW40T100-6 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 4 GHz to 10 GHz bandwidth on a (6) FlexChannel model
6B-BW60T80-6 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 6 GHz to 8 GHz bandwidth on a (6) FlexChannel model
6B-BW60T100-6 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 6 GHz to 10 GHz bandwidth on a (6) FlexChannel model
6B-BW80T100-6 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 8 GHz to 10 GHz bandwidth on a (6) FlexChannel model
MSO68B SUP6B-BW8 6B-BW10T25-8 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 1 GHz to 2.5 GHz bandwidth on a (8) FlexChannel model
6B-BW10T40-8 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 1 GHz to 4 GHz bandwidth on a (8) FlexChannel model
6B-BW10T60-8 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 1 GHz to 6 GHz bandwidth on a (8) FlexChannel model
6B-BW10T80-8 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 1 GHz to 8 GHz bandwidth on a (8) FlexChannel model
6B-BW10T100-8 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 1 GHz to 10 GHz bandwidth on a (8) FlexChannel model
6B-BW25T40-8 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 2.5 GHz to 4 GHz bandwidth on a (8) FlexChannel model
6B-BW25T60-8 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 2.5 GHz to 6 GHz bandwidth on a (8) FlexChannel model
6B-BW25T80-8 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 2.5 GHz to 8 GHz bandwidth on a (8) FlexChannel model
6B-BW25T100-8 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 2.5 GHz to 10 GHz bandwidth on a (8) FlexChannel model
6B-BW40T60-8 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 4 GHz to 6 GHz bandwidth on a (8) FlexChannel model
6B-BW40T80-8 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 4 GHz to 8 GHz bandwidth on a (8) FlexChannel model
6B-BW40T100-8 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 4 GHz to 10 GHz bandwidth on a (8) FlexChannel model
6B-BW60T80-8 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 6 GHz to 8 GHz bandwidth on a (8) FlexChannel model
6B-BW60T100-8 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 6 GHz to 10 GHz bandwidth on a (8) FlexChannel model
6B-BW80T100-8 License; Bandwidth upgrade for 6 Series B MSO; Upgrade from 8 GHz to 10 GHz bandwidth on a (8) FlexChannel model

Additional information

Producent

Tektronix

Produktkategori

Oscilloscopes

Bw

1 GHz, 2 GHz, 4 GHz, 6 GHz, 8 GHz, 10 GHz

Kanaler

8 Channels

This website uses cookies. By continuing to use this site, you accept our use of cookies.  Learn more