+45 31 33 18 19
salg@GOmeasure.dk

Tektronix TCPA300 100 MHz probe amplifier

Tektronix TCPA300 100 MHz probe amplifier

Price on request

TCPA300 Amplifier AC/DC current probe, DC to 100 MHz, (Requires TCP305A or TCP312A or TCP303 probes)

Tektronix TCPA300 100 MHz probe amplifier

The TCP300 and TCP400 Series AC/DC current measurement family is a highly advanced current measurement system for today’s current measurement needs. When connected to Tektronix oscilloscopes with TEKPROBE Level II, TekConnect (w/ TCA-BNC), or TekVPI (w/ TPA-BNC) interfaces, current measurements and calculations are simple and easy.

Key performance specifications

AC/DC measurement capabilities

  • DC – 100 MHz, Current Probe Amplifier (TCPA300) uses:
    • DC – 100 MHz, 30 A DC (TCP312A)
    • DC – 50 MHz, 50 A DC (TCP305A)
    • DC – 15 MHz, 150 A DC (TCP303)
  • DC – 50 MHz, Current Probe Amplifier (TCPA400) Uses:
    • DC – 2 MHz, 750 A DC 1 (TCP404XL) (500 A DC Continuous)

1 Derated with duty cycle

Key features
  • Automatic scaling and units 1 – Oscilloscope on-screen readout of magnitude and amps reduces measurement errors with no more hand calculations
  • AC/DC input coupling
  • Low insertion impedance reduces device under test loading
  • Split-core construction allows easy circuit connection
  • Status indicators provide visual operating status and notification of potential error conditions – degauss, probe open, overload, not terminated into 50 Ω, noncompatible probe type
  • Low DC drift and noise allows improved low-level current measurements
  • 3rd party safety certification

1 Requires a TDS TEKSCOPE oscilloscope or a TekConnect oscilloscope with TCA-BNC adapter

Applications
  • Development and analysis solutions for designers, installers, and service personnel in telecom, data comm, computer, and semiconductor power electronics environments for:

    • Power supplies (switching and linear)
    • Semiconductor devices (SCRs, IGBTs, MOSFETs, CMOS, BJTs)
    • Power inverters/converters
    • Electronic ballasts
    • Industrial/consumer electronics
    • Mobile communications (phone, satellite, relay stations)
    • Motor drives
    • Transportation systems (electronic vehicles, electric trains, locomotives, avionics)

     

Meets today’s AC/DC current measurement applications

The TCPA300 amplifier, when used with TCP312A, TCP305A, or TCP303 probes, provides a wide range of current measurement capability and spans the gap between low-level milliamp measurements to very high current levels. These three probes provide current measurement capabilities of 30 A, 50 A, and 150 A DC continuous. For even higher current levels, the TCPA400 amplifier with the TCP404XL current probe measures 500 A DC continuous and 750 A DC continuous, derated with duty cycle.

Higher-frequency performance is available with the TCP312A w/TCPA300 providing ≥100 MHz bandwidth and a maximum current of 30 A DC.

Measurement errors and manual calculations are now a thing of the past

With this new series of current measurement tools, automatic control and on-screen scaling and units is provided for users of Tektronix TDS3000, TDS500, TDS600, TDS700, TDS5000, TDS6000, and TDS7000B series oscilloscope systems (the DPO3000, MDO/MSO/DPO4000, MSO/DPO5000, and DPO7000 series oscilloscopes, the TPA-BNC adapter is required).

The TCP300/TCP400 current measurement systems seamlessly integrate with your TDS series oscilloscope.

Even non-TEKPROBE systems can use the TCPA300/400 series to make proper current measurements by simply multiplying the measured output voltage on the oscilloscope by the TCPA300/400 series range setting.

Tektronix TCPA300 100 MHz probe amplifier

Tektronix TCPA300 Datasheet

Tektronix TCPA300 100 MHz probe amplifier

Probes

TCP312A Probe
AC/DC current, DC to 100 MHz; 30 A DC (Requires TCPA300 amplifier)
TCP305A Probe
AC/DC current, DC to 50 MHz; 50 A DC (Requires TCPA300 amplifier)
TCP303 Probe
AC/DC current, DC to 15 MHz; 150 A DC (Requires TCPA300 amplifier)
TCP404XL Probe
AC/DC current, DC to 2 MHz; 500 A DC (750 A DC derated with duty cycle) (Requires TCPA400 amplifier)

All TCP300/400 probes include: instructions and a certificate of traceable calibration.

Amplifiers

TCPA300 Amplifier
AC/DC current probe, DC to 100 MHz, (Requires TCP305A or TCP312A or TCP303 probes)
TCPA400 Amplifier
AC/DC current probe, DC to 50 MHz, (Requires TCP404XL probe)

All TCPA300/TCPA400 Current Probe Amplifiers Include: AC/DC current probe amplifier, documentation kit, TEKPROBE interface cable, male-to-male BNC cable (50 Ω), 50 Ω feedthrough termination, certificate of traceable calibration.

 

Recommended accessories
Cover, large probe protective; (for TCP303, TCP404XL)
016-1924-00
Case, transit; current measurement systems
016-1922-00
50 Ω feedthrough termination
011-0049-02
50 Ω BNC-to-BNC coaxial cable
012-0117-00
TEKPROBE interface cable, TCPA300 or TCPA400 amplifier to TDS series oscilloscopes
012-1605-00
Current loop, 1 turn, 50 Ω, BNC connector (for TCP305A, TCP312A, TCP202A)
067-2396-00
Current loop, 1 turn, 50 Ω, BNC connector (for TCP303, TCP404XL)
015-0601-50
TCPA300/TCPA400 amplifier calibration adapter
174-4765-00
Power measurements deskew fixture for TCP202A, TCP305A, TCP312A, TCP303 probes
067-1478-00
Warranty

One year parts and labor.

Power requirements
Amplifiers
90 V to 264 V, 47 to 440 Hz, 50 W; Maximum CAT II (auto switch)
Probes
TCP312A, TCP305A, TCP303 probes require a TCPA300 Amplifier;
TCP404XL probe requires a TCPA400 Amplifier

This website uses cookies. By continuing to use this site, you accept our use of cookies.  Learn more