Hioki CT6846 Current Sensor
Price on request
Hioki AC/DC clamp sensors are best-in-class current sensors for use with power meters, Memory HiCorders and high performance oscilloscopes. The CT6845 is a high-precision 500 A AC/DC current probe that features a wide operating temperature range and large jaw diameter, making them ideal for evaluating the operational integrity of devices that are subject to extreme temperature ranges.
Hioki CT6846 Current Sensor
Hioki CT6846 AC/DC clamp sensors are best-in-class current sensors for use with power meters, Memory HiCorders and high performance oscilloscopes. The CT6846 is a high-precision 1000 A AC/DC current probe that features a wide operating temperature range and large jaw diameter, making them ideal for evaluating the operational integrity of devices that are subject to extreme temperature ranges. A comment from the Good Design Award 2016 “The ergonomic design of these products appropriately reflects conditions in the field as well as worker needs through features such as one-handed operation and a grip that can be easily opened and closed in any orientation. In addition, they exhibit a high level of overall finish, including through the effective use of visual cues, for example use of yellow and gray to prompt the user to interact with the instrument in a way that avoids its inherent hazards.”
Key Features
• Ideal for use in environmental testing with broad -40˚C to 85˚C temperature range
• High precision with a clamp-type design, ±0.3% amplitude accuracy, ±0.1° phase accuracy
• Wide-bandwidth from DC to 100 kHz
• Single-handed operation and robust locking mechanism
• Reduced effects from magnetic fields, conductor position, and noise from nearby wires
• For EV/HEV battery charge and discharge efficiency testing and inverter and power conditioner conversion efficiency evaluations
Rated current | 1000 A AC/DC |
---|---|
Max. allowable input | 1700 A peak (requires derating) |
Frequency characteristics | DC to 20 kHz Phase: DC to 20 kHz |
Amplitude and phase accuracy | DC ±0.3 % rdg. ±0.02 % f.s. (Phase: Not defined) DC < f ≤ 100 Hz ±0.3 % rdg. ±0.01 % f.s. (Phase: ±0.1°) Defined to 20 kHz |
Output voltage | 2 mV/A (voltage output with the Sensor Uni use with a device having a 1 MΩ input resistance or higher) |
Core diameter | φ 50 mm (1.97 in) |
Operating temperature, humidity | -40 °C to +85 °C (-40 °F to 185 °F), 80% RH or less (with no condensation) |
Power supply | ±11 V to ±15 V DC (Power suppled via the Sensor Unit, which supports 100 to 240 V AC) |
Power consumption | 7 VA max. (at 1000 A/55 Hz, ±12 V power requirement) |
Dimensions and mass | 238 mm (9.37 in)W × 116 mm (4.57 in)H × 35 mm (1.38 in)D, 990 g (34.9 oz), cord length: 3 m (9.84 ft) |
Accessories | Instruction manual ×1, Mark bands ×6, Carrying Case |
Compatible models…CT6846 (-05)
Compatible models | CT6846 | CT6846-05 |
---|---|---|
Power Analyzer PW6001, PW3390 | △ (Requires CT9900, CT ratio 2) | OK |
Power Analyzer 3390 | OK (CT ratio 2) | △ (Requires CT9901, CT ratio 2) |
Power HiTester 3193 series | OK (CT ratio 2) | △ (Requires CT9901, CT ratio 2) |
Current Unit 8971 | △ (Requires the 9318, CT ratio 2) | △ (Requires the 9318, CT9901, CT ratio 2) |
F/V Unit 8940 | △ (Requires the 9318, 9705, CT ratio 2) | △ (Requires the 9318, 9705, CT9901, CT ratio 2) |
Hioki CT6846 Current Sensor
Hioki CT6846 Current Sensor
CT6846 | 1000 A AC/DC, PL23 terminal |
---|---|
CT6846-05 | 1000 A AC/DC, ME15W terminal |
Additional information
Producent | Hioki |
---|---|
Produktkategori | Oscilloscope Probes |